This article provides a list of commands that can be used at a site with an FSC3000 or a System2 controller.
The * symbol in the commands indicates a number entry.
COMMANDS AND DESCRIPTIONS
show system
- Displays site parameters.
install pct * pos *
- Re-installs a PCT (Pump Control Terminal) or position.
remove pct * pos *
- Removes a PCT or position.
show pct * / show pct * pos *
- Shows the PCT's and/or positions at the site. Can be used to identify pump numbers and pump parameters.
config pct * / config pct * pos * / config pump *
- Used to configure pump parameters (e.g., pulses per litre, max fueling time, etc.).
config fit *
- Used to configure the FIT (Fuel Island Terminal). Can also be used to disable or enable the receipt printer.
dwn
- Should be used at the end of the command line to ensure the controller downloads all commands. Commands will not work unless this is done.
~prst
- Reboots the FSC3000.
test
- Has the option to reboot the System2 controller. Can also be used on the FSC3000 to run diagnostic tests.
━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
⚠️ Always use the dwn command at the end of your command sequence. Without it, the controller will not download or apply the commands executed.
⚠️ When using the test command to reboot a System2 controller, the system will ask if you want to perform a "cold start." Always hit "N" (No). A cold start will factory reset all settings and erase the configuration.